Home / Products / Solar Home & Off-Grid Systems

APOLLO A Series Inverter with Energy Storage
Six-module stack for the 230 V market: a 6 kW or 12 kW inverter above 51.2 V battery modules from 5.12 kWh to 30.72 kWh, assembled on site and connected through one AC input, one PV input and one battery bus.
- Rated power: 6 kW / 12 kW
- Battery: 51.2 V, 5120 Wh per module
- Capacity: 5.12 kWh to 30.72 kWh
- AC output: 230 VAC
- Efficiency: ≥98%
- Max charge / discharge: 200 A / 200 A
- PV input: 9000 W, 80–500 VDC
- Cycle life: ≥6000 cycles
Request a quotation for APOLLO A Series Inverter with Energy Storage
Quantity, destination port and your contact details are enough for us to price it. Tell us the pole height or road class if you have them.
Six-module stack for the 230 V market: a 6 kW or 12 kW inverter above 51.2 V battery modules from 5.12 kWh to 30.72 kWh, assembled on site and connected through one AC input, one PV input and one battery bus.
At a glance
| Model | SCAP-A-51.2-100 / 200 / 300 / 400 / 500 / 600 |
| Rated power | 6 kW / 12 kW |
| AC rated voltage | 230 VAC |
| Rated frequency | 50 / 60 Hz |
| Efficiency | ≥98% |
| Transfer time | 10 ms |
| Waveform | Pure sinusoidal wave |
| Battery overvoltage | 58.4 V |
| Battery undervoltage alarm | 45 V |
| Constant voltage charge | 58.4 V |
| Float voltage | 56 V |
| Max charging current | 100 A / 160 A |
Where the Apollo A fits
A six-module stack for the 230 V market: a 6 kW or 12 kW inverter sitting above 51.2 V battery modules from 5.12 kWh to 30.72 kWh, assembled on site and connected through one AC input, one PV input and one battery bus. Because it arrives as modules rather than a sealed cabinet, the same product covers a small shop and a large house without a different SKU.
Cycle life is ≥6,000 at 0.5C to 80% end of life, and depth of discharge is 95%. Compared with the Apollo B — a three-module cabinet — the A series scales further but needs the site to do the stacking; the Apollo C is the two-module version for the largest single-unit capacities.
- 6 kW or 12 kW inverter; 5.12–30.72 kWh in 51.2 V modules.
- Efficiency ≥98%; RS485 to the BMS, USB at the inverter.
- Site assembly required — confirm who is doing the stacking and commissioning.
The full table, including every model in the range, is on the Technical Parameters tab.
APOLLO A Series Inverter with Energy Storage — technical parameters
| Inverter | |
| Model | SCAP-A-51.2-100 / 200 / 300 / 400 / 500 / 600 |
| Rated power | 6 kW / 12 kW |
| AC rated voltage | 230 VAC |
| Rated frequency | 50 / 60 Hz |
| Efficiency | ≥98% |
| Transfer time | 10 ms |
| Waveform | Pure sinusoidal wave |
| Battery overvoltage | 58.4 V |
| Battery undervoltage alarm | 45 V |
| Constant voltage charge | 58.4 V |
| Float voltage | 56 V |
| Max charging current | 100 A / 160 A |
| Communication interface | USB (inverter) / RS485 (BMS) |
| Dimension | 60 × 40.5 × 18 cm / 60 × 40.5 × 22 cm |
| AC input | |
| Nominal voltage | 230 VAC |
| Voltage range | 90–280 VAC |
| Rated frequency | 50 / 60 Hz |
| Frequency range | 40–70 Hz |
| Rated current | 60 A |
| Max AC current | 100 A / 160 A |
| PV input | |
| Max voltage | 500 V |
| Optimum voltage | 300–400 V |
| Voltage range | 80–500 VDC |
| Max power | 27 A / 9000 W (6 kW) · 27 A + 27 A / 7500 W × 2 (12 kW) |
| Battery | |
| Rated capacity | 5120 / 10240 / 15360 / 20480 / 25600 / 30720 Wh |
| Nominal voltage | 51.2 V |
| Discharge voltage range | 43.2–58.4 V |
| Standard charging current | 50 A / 100 A |
| Max charging current | 100 A / 200 A |
| Max discharging current | 100 A / 200 A |
| Depth of discharge | 95% |
| Communication interface | CAN / RS485 |
| Cycle life | ≥6000 cycles, 25±2 °C, 0.5C, EOL80% |
| Working temperature | Charge 0–50 °C, discharge −20–60 °C |
| Storage temperature | −20–60 °C |
| Dimension | 60 × 40.5 × 19.5 cm |
Tell us the daily load, the backup hours you need and the PV array size and we will confirm the model and the configuration for your project.