Home / Products / Solar Home & Off-Grid Systems

ARES Series All-in-One Solar System
Integrated inverter and battery cabinet in four capacities, from a 5 kW inverter with 5120 Wh up to a 12 kW inverter with 15360 Wh, delivered as a single unit with plug-and-play connections.
- Rated power: 5 kW to 12 kW
- Battery: LiFePO4, 25.6 V / 51.2 V
- Capacity: 5 kWh to 15 kWh
- AC output: 230 VAC
- Efficiency: ≥98%
- Depth of discharge: 95%
- PV input: 9000 W / 15000 W
- Cycle life: ≥6000 / ≥8000 cycles
Request a quotation for ARES Series All-in-One Solar System
Quantity, destination port and your contact details are enough for us to price it. Tell us the pole height or road class if you have them.
Integrated inverter and battery cabinet in four capacities, from a 5 kW inverter with 5120 Wh up to a 12 kW inverter with 15360 Wh, delivered as a single unit with plug-and-play connections.
At a glance
| Model | SCAS-5.5KW-5KWH · SCAS-5KW-7.5KWH/8.5KWH · SCAS-5.5KW-10KWH · SCAS-11KW-15KWH |
| Rated power | 5 kW · 5 kW · 6 kW · 12 kW |
| AC rated voltage | 230 VAC |
| Rated frequency | 50 / 60 Hz |
| Efficiency | ≥98% |
| Transfer time | 10 ms |
| Waveform | Pure sinusoidal wave |
| Battery overvoltage | 29.2 V · 29.2 V · 58.4 V · 58.4 V |
| Battery undervoltage alarm | 22.5 V · 22.5 V · 45 V · 45 V |
| Constant voltage charge | 29.2 V · 29.2 V · 58.4 V · 58.4 V |
| Protection voltage | 21.6 V · 21.6 V · 43.2 V · 43.2 V |
| Float voltage | 28 V · 28 V · 56 V · 56 V |
Where the Ares fits
An integrated inverter-and-battery cabinet in four capacities: from a 5 kW inverter with 5,120 Wh up to a 12 kW inverter with 15,360 Wh, delivered as one unit with plug-and-play connections. It is the range to quote when the buyer wants a single box rather than a stack of modules.
Note the split in the table: the two smaller models run a 25.6 V battery bus, the two larger ones 51.2 V, and the cycle life steps from 6,000 to 8,000 cycles between them. That means the Ares range is really two families in one page — confirm which side of the split the project needs before comparing prices.
- Four models: 5 kW/5.12 kWh, 5.5 kW, 11 kW/10.24 kWh, 12 kW/15.36 kWh.
- 25.6 V on the small pair, 51.2 V on the large pair; ≥8,000 cycles on the larger two.
- Single-unit delivery — ask for the packed weight, it is a two-person lift.
The full table, including every model in the range, is on the Technical Parameters tab.
ARES Series All-in-One Solar System — technical parameters
| Models | |
| Model | SCAS-5.5KW-5KWH · SCAS-5KW-7.5KWH/8.5KWH · SCAS-5.5KW-10KWH · SCAS-11KW-15KWH |
| Rated power | 5 kW · 5 kW · 6 kW · 12 kW |
| Output | |
| AC rated voltage | 230 VAC |
| Rated frequency | 50 / 60 Hz |
| Efficiency | ≥98% |
| Transfer time | 10 ms |
| Waveform | Pure sinusoidal wave |
| Battery management | |
| Battery overvoltage | 29.2 V · 29.2 V · 58.4 V · 58.4 V |
| Battery undervoltage alarm | 22.5 V · 22.5 V · 45 V · 45 V |
| Constant voltage charge | 29.2 V · 29.2 V · 58.4 V · 58.4 V |
| Protection voltage | 21.6 V · 21.6 V · 43.2 V · 43.2 V |
| Float voltage | 28 V · 28 V · 56 V · 56 V |
| Max charging current | 200 A · 200 A · 100 A · 200 A |
| Communication interface | USB (inverter) / RS485 (BMS) |
| AC input | |
| Nominal voltage | 230 VAC |
| Voltage range | 90–280 VAC |
| Rated frequency | 50 Hz |
| Frequency range | 40–70 Hz |
| Rated current | 60 A |
| Max AC current | 160 A · 160 A · 120 A · 160 A |
| PV input | |
| Max voltage | 500 V |
| Optimum voltage | 300–400 V |
| Voltage range | 60–500 VDC · 60–500 VDC · 80–500 V · 80–500 V |
| Max power | 27 A / 9000 W · 27 A / 9000 W · 27 A / 9000 W · 27 A + 27 A / 15000 W |
| Battery | |
| Rated capacity | 5120 Wh (200 Ah) · 7680 Wh (300 Ah) · 10240 Wh (200 Ah) · 15360 Wh (300 Ah) |
| Nominal voltage | 25.6 V · 25.6 V · 51.2 V · 51.2 V |
| Discharge voltage range | 21.6–29.2 V · 21.6–29.2 V · 43.2–58.4 V · 43.2–58.4 V |
| Standard charging current | 100 A · 100 A · 50 A · 100 A |
| Max charging current | 200 A · 200 A · 100 A · 200 A |
| Max discharging current | 200 A · 200 A · 100 A · 200 A |
| Depth of discharge | 95% |
| Communication interface | CAN / RS485 |
| Cycle life | ≥6000 cycles · ≥8000 cycles, 25 ±2 °C, 0.5C, EOL80% |
| Working temperature | Charge 0–50 °C, discharge −20–60 °C |
| Storage temperature | −20–60 °C |
| Dimension | 45.2×73×27 cm · 45×77×29 cm · 48×84×30 cm · 57×78×40 cm |
Tell us the daily load, the backup hours you need and the PV array size and we will confirm the model and the configuration for your project.