Home / Products / Solar Home & Off-Grid Systems

High Voltage Rack Mounted Battery System
Rack-mounted LiFePO4 system built from 5 kWh, 10 kWh or 16.07 kWh modules in series: 204.8 V to 819.2 V system voltage and 20.48 kWh to 257.2 kWh per stack, for commercial and off-grid plant rooms.
- Chemistry: LiFePO4
- Module energy: 5 kWh / 10 kWh / 16.07 kWh
- System voltage: 204.8 V to 819.2 V
- System energy: 20.48 kWh to 257.2 kWh
- Protection: IP20, rack mounted
- Certification: UN38.3, CE, IEC62619
Request a quotation for High Voltage Rack Mounted Battery System
Quantity, destination port and your contact details are enough for us to price it. Tell us the pole height or road class if you have them.
Rack-mounted LiFePO4 system built from 5 kWh, 10 kWh or 16.07 kWh modules in series: 204.8 V to 819.2 V system voltage and 20.48 kWh to 257.2 kWh per stack, for commercial and off-grid plant rooms.
At a glance
| Model | SCRA-R-51.2-100 (HV) / SCRA-R-51.2-200 (HV) / SCRA-R-51.2-314 (Ah) |
| Chemical battery | LiFePO4 |
| Module energy | 5 kWh / 10 kWh / 16.07 kWh |
| Module rated voltage | 51.2 V |
| Module capacity | 100 Ah / 200 Ah / 314 Ah |
| Modules in series | 4 (min) – 8 – 16 · 4 (min) – 6 – 16 · 4 (min) – 8 – 16 |
| System rated voltage | 204.8 V / 409.6 V / 819.2 V |
| System operating voltage | 172.8–233.6 V · 345.6–467.2 V · 691.2–934.4 V (per configuration) |
| System energy | 20.48 / 40.96 / 81.92 kWh · 40.96 / 61.44 / 163.84 kWh · 64.3 / 128.6 / 257.2 kWh |
| Charge / discharge current | Recommended 50 / 100 / 120 A, max 75 / 120 / 150 A |
| Working temperature | Charge 0–55 °C, discharge −20–55 °C |
| Communication | CAN2.0 / RS485 |
Where the high-voltage rack fits
A rack-mounted system built from 5 kWh, 10 kWh or 16.07 kWh modules in series, giving 204.8–819.2 V system voltage and 20.48–257.2 kWh per stack. High voltage is the point: at these voltages the current stays low, so cable sizes and losses drop compared with a 51.2 V bank of the same capacity.
It carries UN38.3, CE and IEC62619, with ≥6,000 cycles on the 100/200 Ah modules and ≥8,000 on the 314 Ah module, BMS protection across all five fault classes, and CAN2.0 / RS485 communication. This is plant-room equipment for commercial and off-grid sites; for a single household the ATHENA C cabinet is the right scale.
- 204.8–819.2 V; 20.48–257.2 kWh per stack; 16S per module.
- UN38.3 / CE / IEC62619; altitude ≤2,000 m.
- Cabinet heights up to 2,100 mm — confirm the plant-room door and ceiling.
The full table, including every model in the range, is on the Technical Parameters tab.
High Voltage Rack Mounted Battery System — technical parameters
| Model | SCRA-R-51.2-100 (HV) / SCRA-R-51.2-200 (HV) / SCRA-R-51.2-314 (Ah) |
| Chemical battery | LiFePO4 |
| Module energy | 5 kWh / 10 kWh / 16.07 kWh |
| Module rated voltage | 51.2 V |
| Module capacity | 100 Ah / 200 Ah / 314 Ah |
| Modules in series | 4 (min) – 8 – 16 · 4 (min) – 6 – 16 · 4 (min) – 8 – 16 |
| System rated voltage | 204.8 V / 409.6 V / 819.2 V |
| System operating voltage | 172.8–233.6 V · 345.6–467.2 V · 691.2–934.4 V (per configuration) |
| System energy | 20.48 / 40.96 / 81.92 kWh · 40.96 / 61.44 / 163.84 kWh · 64.3 / 128.6 / 257.2 kWh |
| Charge / discharge current | Recommended 50 / 100 / 120 A, max 75 / 120 / 150 A |
| Working temperature | Charge 0–55 °C, discharge −20–55 °C |
| Communication | CAN2.0 / RS485 |
| Humidity | 5–85% RH |
| Altitude | ≤2000 m |
| Protection degree | IP20 |
| Installation | Rack mounted |
| Storage temperature | −20–60 °C |
| Depth of discharge | 95% |
| Cycle life | ≥6000 cycles (100 / 200 Ah models), ≥8000 cycles (314 Ah) |
| Certification | UN38.3, CE, IEC62619 |
| Cell configuration | 16S per module |
| Round-trip efficiency | ≥95% |
| Self-discharge | ≤3% per month at 25 °C |
| BMS protection | Over-charge, over-discharge, over-current, over-temperature, short circuit |
| Design life | ≥10 years at 25 °C |
| Dimension (W×D×H) | 540×600×900 / 1500 / 2100 mm · 580×540×1370 / 1840 mm · 505×740×1416 / 2112 mm |
Tell us the daily load, the backup hours you need and the PV array size and we will confirm the model and the configuration for your project.