Home / Products / Solar Home & Off-Grid Systems

APOLLO C Series Inverter with Energy Storage (US Version)
Two-module cabinet for the 110 V split-phase market: a 10 kW inverter with 15360 Wh or 30720 Wh of 51.2 V battery capacity, factory-assembled as a floor-standing unit with castors.
- Rated power: 10 kW
- AC output: 110 V / 230 V (split phase)
- Capacity: 15.36 kWh / 30.72 kWh
- PV input: 6400 W max, 60–150 V
- Efficiency: ≥98%
- Cycle life: ≥8000 cycles
Request a quotation for APOLLO C Series Inverter with Energy Storage (US Version)
Quantity, destination port and your contact details are enough for us to price it. Tell us the pole height or road class if you have them.
Two-module cabinet for the 110 V split-phase market: a 10 kW inverter with 15360 Wh or 30720 Wh of 51.2 V battery capacity, factory-assembled as a floor-standing unit with castors.
At a glance
| Model | SCAP-51.2-300 (10 kW + 15 kWh) / SCAP-51.2-600 (10 kW + 30 kWh) |
| Rated power | 10 kW |
| AC rated voltage | 110 V / 230 V (split phase) |
| Rated frequency | 50 / 60 Hz |
| Efficiency | ≥98% |
| Transfer time | 10 ms |
| Waveform | Pure sinusoidal wave |
| Battery overvoltage | 58.4 V |
| Battery undervoltage alarm | 45 V |
| Constant voltage charge | 58.4 V |
| Float voltage | 56 V |
| Max charging current | 160 A |
Where the Apollo C US fits
The 110 V split-phase version of the Apollo C cabinet: a 10 kW inverter with 15,360 Wh or 30,720 Wh of 51.2 V battery, factory-assembled on castors. Split phase matters in North American and some Latin American installations — a 230 V single-phase cabinet cannot feed two 110 V legs, so this is a different electrical product, not a variant label.
Cell life is ≥8,000 cycles at 0.5C, and the BMS communicates over CAN or RS485. For a 230 V market the equivalent is the standard Apollo C; where the load is smaller, the Apollo B cabinet covers 5–20 kWh at 6 kW.
- 10 kW, 110 V / 230 V split phase; 15,360 or 30,720 Wh at 51.2 V.
- AC input 50 A rated / 100 A max, 50/60 Hz.
- Confirm the utility configuration with the installer before ordering — this is the one model where the wrong phase is a return shipment.
The full table, including every model in the range, is on the Technical Parameters tab.
APOLLO C Series Inverter with Energy Storage (US Version) — technical parameters
| Model | SCAP-51.2-300 (10 kW + 15 kWh) / SCAP-51.2-600 (10 kW + 30 kWh) |
| Rated power | 10 kW |
| AC rated voltage | 110 V / 230 V (split phase) |
| Rated frequency | 50 / 60 Hz |
| Efficiency | ≥98% |
| Transfer time | 10 ms |
| Waveform | Pure sinusoidal wave |
| Battery overvoltage | 58.4 V |
| Battery undervoltage alarm | 45 V |
| Constant voltage charge | 58.4 V |
| Float voltage | 56 V |
| Max charging current | 160 A |
| Communication | RS232 (inverter) / RS485 (BMS) |
| AC input voltage | 110 VAC nominal, 77–135 VAC |
| AC input frequency | 50 / 60 Hz, 40–70 Hz |
| AC input current | 50 A rated / 100 A max |
| PV max voltage | 150 V |
| PV optimum voltage | 60–105 V |
| PV max power | 6400 W |
| Battery rated capacity | 15360 Wh (300 Ah) / 30720 Wh (600 Ah) |
| Battery nominal voltage | 51.2 V |
| Discharge voltage range | 43.2–58.4 V |
| Max charge / discharge current | 200 A / 200 A |
| Depth of discharge | 95% |
| Battery communication | CAN / RS485 |
| Cycle life | ≥8000 cycles, 25±2 °C, 0.5C, EOL80% |
| Working temperature | Charge 0–50 °C, discharge −20–60 °C |
| Storage temperature | −20–60 °C |
| Dimension | 70 × 26 × 51 cm |
Tell us the daily load, the backup hours you need and the PV array size and we will confirm the model and the configuration for your project.