Home / Products / Solar Home & Off-Grid Systems

APOLLO C Series Inverter with Energy Storage
Two-module cabinet for larger loads on a 230 V supply: a 6 kW or 12 kW inverter paired with 15360 Wh to 30720 Wh of 51.2 V battery capacity, in a floor-standing format with castors.
- Rated power: 6 kW / 12 kW
- Battery: 51.2 V
- Capacity: 15.36 kWh to 30.72 kWh
- AC output: 230 VAC
- Efficiency: ≥98%
- Max charge / discharge: 200 A / 200 A
- PV input: 9000 W / 15000 W
- Cycle life: ≥8000 cycles
Request a quotation for APOLLO C Series Inverter with Energy Storage
Quantity, destination port and your contact details are enough for us to price it. Tell us the pole height or road class if you have them.
Two-module cabinet for larger loads on a 230 V supply: a 6 kW or 12 kW inverter paired with 15360 Wh to 30720 Wh of 51.2 V battery capacity, in a floor-standing format with castors.
At a glance
| Model | SCAP-C-51.2-300 (6 kW) / SCAP-C-51.2-300 (12 kW) / SCAP-C-51.2-600 (12 kW) |
| Rated power | 6 kW / 12 kW |
| AC rated voltage | 230 VAC |
| Rated frequency | 60 Hz |
| Efficiency | ≥98% |
| Transfer time | 10 ms |
| Waveform | Pure sinusoidal wave |
| Battery overvoltage | 58.4 V |
| Battery undervoltage alarm | 45 V |
| Constant voltage charge | 58.4 V |
| Float voltage | 56 V |
| Max charging current | 120 A / 160 A |
Where the Apollo C fits
Two modules instead of three, for the largest capacities in the 230 V range: 15.36–30.72 kWh at 51.2 V, paired with a 6 kW or 12 kW inverter, in a floor-standing cabinet on castors. The cells are rated ≥8,000 cycles at 0.5C — higher than the 6,000-cycle A and B series — which matters on a daily-cycle duty.
Peak discharge reaches 200 A, so the cabinet can carry a 12 kW inverter's surge without tripping. Compared with the Apollo B it doubles the usable energy in a similar footprint; for the 110 V split-phase market, see the US version.
- Two-module cabinet; 15.36 or 30.72 kWh; 6 or 12 kW inverter.
- ≥8,000 cycles, 95% DoD, ≥98% efficiency.
- Confirm the AC configuration — 230 V single phase is the default, the US unit is split phase.
The full table, including every model in the range, is on the Technical Parameters tab.
APOLLO C Series Inverter with Energy Storage — technical parameters
| Inverter | |
| Model | SCAP-C-51.2-300 (6 kW) / SCAP-C-51.2-300 (12 kW) / SCAP-C-51.2-600 (12 kW) |
| Rated power | 6 kW / 12 kW |
| AC rated voltage | 230 VAC |
| Rated frequency | 60 Hz |
| Efficiency | ≥98% |
| Transfer time | 10 ms |
| Waveform | Pure sinusoidal wave |
| Battery overvoltage | 58.4 V |
| Battery undervoltage alarm | 45 V |
| Constant voltage charge | 58.4 V |
| Float voltage | 56 V |
| Max charging current | 120 A / 160 A |
| Communication interface | USB (inverter) / RS485 (BMS) |
| Dimension | 70 × 26 × 51 cm |
| AC input | |
| Nominal voltage | 230 VAC |
| Voltage range | 90–280 VAC |
| Rated frequency | 50 / 60 Hz |
| Frequency range | 40–70 Hz |
| Rated current | 60 A |
| Max AC current | 120 A / 160 A |
| PV input | |
| Max voltage | 500 V |
| Optimum voltage | 300–400 V |
| Voltage range | 80–500 VDC |
| Max power | 27 A / 9000 W (6 kW) · 27 A + 27 A / 15000 W (12 kW) |
| Battery | |
| Rated capacity | 15360 Wh (300 Ah) / 15360 Wh (300 Ah) / 30720 Wh (600 Ah) |
| Nominal voltage | 51.2 V |
| Discharge voltage range | 43.2–58.4 V |
| Standard charging current | 100 A |
| Max charging current | 200 A |
| Max discharging current | 200 A |
| Depth of discharge | 95% |
| Communication interface | CAN / RS485 |
| Cycle life | ≥8000 cycles, 25±2 °C, 0.5C, EOL80% |
| Working temperature | Charge 0–50 °C, discharge −20–60 °C |
| Storage temperature | −20–60 °C |
| Dimension | 70 × 26 × 51 cm |
Tell us the daily load, the backup hours you need and the PV array size and we will confirm the model and the configuration for your project.